Summary
For the chemical
and petrochemical industry, SDL offers a wide range of gas analysis systems. We
offer analyzers for H2, N2, O2, CO, CO2
and other components such as ethylene, polyethylene, polypropylene, styrene,
methanol, and acetic acid.
Typical
measuring components
Sample point
|
Measuring components & range
|
The typical analyzer applied
|
O2 analysis in the semi-water coal gas
|
0~1% O2
|
MODEL 1080-PO magnetic oxygen analyzer
|
CO analysis in converter gas
|
0~2.5% CO
|
MODEL 1080Ex infrared gas analyzer
|
CO2 analysis in purification section
|
0~8% CO2
|
MODEL 1080Ex infrared gas analyzer
|
CO2 analysis in purification section
|
0~1% CO2
|
MODEL 1080Ex infrared gas analyzer
|
CO2 analysis in purification section
|
80~100% CO2
|
ULTRAMAT 6F Ex infrared gas analyzer
|
CO, CO2 analysis in the sample gas inlet
to copper washing tower
|
0~1% CO2, 0~5% CO
|
MODEL 1080Ex infrared gas analyzer
|
CO, CO2 analysis in the sample gas outlet
to copper washing tower
|
0~250 ppm CO2
0~50 ppm CO
|
ULTRAMAT 6F Ex infrared gas analyzer
|
CO, CO2 analysis in the sample gas outlet
of ammonia washing tower
|
0~50 ppm CO + CO2
|
ULTRAMAT 6F Ex infrared gas analyzer
|
NH3 analysis in the sample gas outlet of
ammonia washing tower
|
0~25% NH3
|
MODEL 1080Ex infrared gas analyzer
|
Multi-component analysis in the process gases
|
NH3, CH4, Ar, N2, H2
|
MAXUM Ⅱ process gas chromatography
|
CO, CO2 analysis in the sample gas of
methanol production
|
0~20%
|
MODEL 1080 Ex infrared gas analyzer
|
H2 analysis in the urea synthetic
|
H2
|
MODEL 1080 Ex-TC thermal conductivity analyzer
|
Exhaust gas emission analysis
|
SO2, NO, O2, dust,
temperature, pressure, etc.
|
SCS-900 continuous emission monitoring system |